M1-G04 — 关节标定边界¶
Links / 链接: M1-Hardware-Ground-Truth · T-ACT-002-Servo-Coordinate-Calibration-Contract · evidence-registry
Status¶
PASS WITH DECLARED BOUNDARY
Objective¶
冻结 M1 所需的 controller command calibration facts,并严格区分 reference command、servo_off 与 mechanical u0;不得把缺失的 external joint ground truth 伪装成 M1 blocker。
Acceptance Criteria¶
| Criterion ID | Requirement | Evidence#Part | Status | Notes |
|---|---|---|---|---|
| M1-G04-C01 | 8 路 Servo reference command 冻结 | E-M1-002#P03 | PASS | [112,214,146,237,113,214,133,252] deg |
| M1-G04-C02 | servo_off trim 冻结且不冒充 mechanical zero | E-M1-002#P03; E-FW-003#P03 | PASS | [-4,-5,+5,-7,-3,-5,-8,+8] deg |
| M1-G04-C03 | command-to-PWM/count mapping 与 software range frozen | E-FW-001#P03 | PASS | 50 Hz; 500-2500 us; 0-300 deg is not mechanical range |
| M1-G04-C04 | 未测 mechanical u0、q_real/qd_real、absolute sign 被显式分类 | E-M1-002#P05 | PASS | Optional Ground Truth / Deployment, not inferred |
Boundary¶
Powered Servo motion proves command execution and return, not measured physical angle. Wheel raw command is not relabeled as rad/s, N*m, or A. This Gate does not fit deadband, scale, stiffness, or damping; those belong to M3 Dynamics.
Changelog / 更新日志¶
- 2026-09-17:按 M1 Real physical contract correction 重写验收边界;reference、trim 和 mechanical zero 严格分离,Gate 置 PASS WITH DECLARED BOUNDARY。
- 2026-09-15:旧 Gate 将 external mechanical measurement 作为必需项,现已按 ownership correction 清理。