T-ACT-002 — Servo Coordinate & Calibration Contract

Links / 链接: M1-Hardware-Ground-Truth · M1-G04-关节标定 · T-ACT-001-Canonical-Real-Sim-Component-Identity · evidence-registry

Status

CONTROLLER CONTRACT FROZEN / DEPLOYMENT TRANSFORM PARTIAL

Scope

本 Topic 严格区分三类量:

Quantity Meaning Current status
reference command normal IK 启动/返回姿态下的 post-offset absolute Servo command FROZEN
servo_off firmware 对各通道 IK 输出施加的 assembly trim FROZEN
mechanical u0 canonical physical joint frame 的机械零位 OPTIONAL_EXTERNAL_GROUND_TRUTH

reference command 与 servo_off 均不得当作 measured q_real、qd_real 或 mechanical u0。

Frozen PCA Contract

PCA Canonical Servo Reference command (deg) servo_off (deg) Powered execution/return
1 FR_Outer_Servo 112 -4 PASS
2 FR_Inner_Servo 214 -5 PASS
3 FL_Inner_Servo 146 +5 PASS
4 FL_Outer_Servo 237 -7 PASS
5 RL_Outer_Servo 113 -3 PASS
6 RL_Inner_Servo 214 -5 PASS
7 RR_Inner_Servo 133 -8 PASS
8 RR_Outer_Servo 252 +8 PASS

Evidence: E-M1-002#P02-P04. The historical ch7 failure remains in E-CAL-001#P04 but is no longer the current status after the powered all-channel regression.

Controller Mapping

Firmware maps target degrees to PCA9685 output at 50 Hz:

pulse_us = 500 + 2000 * target / 300
off = floor(pulse_us * 4096 / 20000)

The software interval 0..300 deg is an API representation range, not a mechanical safe range. Powered +/-10 deg commands established visible bounded motion and return, not measured physical angle.

Physical Direction Boundary

  • Historical 2026-09-10 observation recorded PCA4 +command as CW, PCA5 as CCW, and PCA6 as CW under that session's observer convention.
  • Powered Dataset 004 confirmed all PCA channels move and return safely, but Human did not provide reliable per-channel physical direction labels.
  • A portable joint-positive sign requires a canonical body/joint-axis convention. That transform belongs to Deployment, not the frozen M1 identity contract.
  • Sim mirror symmetry must not be used to invent Real physical polarity.

External Ground Truth Boundary

Servo q_real/qd_real, precision mechanical u0, physical deadband, compliance, stiffness, damping, and exact command-to-angle scale are not available from the onboard controller. They remain Optional External Ground Truth or M3 Dynamics, and are not a blocker for M1 closure.

Engineering Conclusion

M1 freezes command identity, reference, trim, PWM/count mapping, powered execution, and return. REAL_COMMAND_PHYSICAL_CONTRACT remains PARTIAL only because absolute physical coordinate signs and external joint measurements are unresolved. No additional powered M1 experiment is required.

更新日志

  • 2026-09-17:移除过时的 ch7 current blocker,导入 E-M1-002 powered all-channel regression;严格分离 reference command、servo_off 与 mechanical u0。